| Nominal Battery System Voltage | 24V | 48V | 24V | 48V | 48V | 48VDC | 48VDC | 48VDC |
| INVERTER OUTPUT |
|---|
| Rated power | 4KW | 5KW | 6KW | 8.0KW | 10.0KW | 12.0KW |
| Surge rating | 12000VA | 15000VA | 18000VA | 24000VA | 30000VA | 36000VA |
| Capable of starting electric motor | 2HP | 2HP | 3HP | 4HP | 5HP | 6HP |
| Waveform | Pure sine wave / same as input (bypass mode) |
| Nominal output voltage RMS | 220V / 230V / 240VAC (±10%RMS) |
| Output frequency | 50Hz / 60Hz ± 0.3Hz |
| Inverter effciency(peak) | >85% | >88% |
| Line mode efficiency | >95% |
| Power factor | 1.0 |
| Typical transfer time | 20ms(max) |
| AC INPUT |
|---|
| Voltage | 230VAC |
| Selectable voltage range | 90-280 VAC (APL) |
| Frequency range | 50Hz / 60Hz |
| BATTERY |
|---|
| Low battery voltage cutoff | 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode) |
| Low battery voltage recover | 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode) |
| High battery voltage cutoff | 30VDC for 24VDC mode (60VDC for 48VDC mode) |
| High battery voltage recover | 28.5VDC for 24VDC mode (57VDC for 48VDC mode) |
| Idle consumption-search mode | <30W when power saver on | <80W when power saver on |
| AC CHARGER |
|---|
| Output voltage | Depends on battery type |
| Charger AC input breaker rating | 40A | 40A | 50A | 80A | 80A | 80A |
| Overcharge protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) |
| Maximum charge current | 80A | 60A | 100A | 70A | 80A | 100A | 120A | 140A |
| BTS |
|---|
| Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature |
| BYPASS & PROTECTION |
| Input voltage waveform | Sine wave (grid or generator) |
| Nominal input frequency | 50Hz or 60Hz |
| Overload protection (SMPS Load) | Circuit breaker |
| Output short circuit protection | Circuit breaker |
| Bypass breaker rating | 40A | 63A | 63A | 63A |
| Max bypass current | 40Amp | 80Amp |
| SOLAR CHARGER |
|---|
| Maximum PV charge current | 80A | 100A(200A optional) |
| DC voltage | 24V / 48V Auto work | 48V |
| Maximim PV array power | 2000W | 4000W | 2000W | 4000W | 4000W | 5000W(10000W for 200A optional) |
| MPPT range @ operating voltage(VDC) | 32-145VDC for 24V mode,64-145V for 48V mode | 64~145VDC |
| Maximum PV array open circuit voltage | 145VDC |
| Maximum effciency | >98% |
| Standby power consumption | <2W |
| MECHANICAL SPECIFICATIONS |
|---|
| Mounting | Wall mount |
| Dimensions (W*H*D) | 620*385*215mm | 670*410*215mm |
| Net weight (solar CHG) (kg) | 36 | 41 | 41 | 69+2.5 | 75.75+2.5 | 75.75+2.5 |
| Shipping dimensions (W*H*D) | 755*515*455mm | 884*618*443mm |
| Shipping weight (Solar CHG) (kg) | 56 | 61 | 64 | 82.5+2.5 | 89+2.5 | 92+2.5 |
| OTHER |
|---|
| Operation temperature range | 0°C to 40°C |
| Storage temperature | -15°C to 60°C |
| Audible noise | 60dB MAX |
| Display | LED+LCD |
| Loading (20GP/40GP/40HQ) | 140pcs / 280pcs / 320pcs |